Product documentation
Technical drawing
Dimension | 80 x 40 x 80 mm |
Style Housing | block style |
Installation | non-flush |
Range | 0…50 mm |
Analog output | Analog, voltage 0…10 V |
Product documentation
Technical drawing
Dimension | 80 x 40 x 80 mm |
Style Housing | block style |
Installation | non-flush |
Range | 0…50 mm |
Analog output | Analog, voltage 0…10 V |
Dimension | 80 x 40 x 80 mm |
Style Housing | block style |
Installation | non-flush |
Range | 0…50 mm |
Analog output | Analog, voltage 0…10 V |
Output characteristic | falling on approach |
Limit frequency –3 dB | 15 Hz |
Repeat accuracy | ±12 µm |
Non-linearity max. | ±750 µm [15…35 mm]; ±1500 µm [5…15 mm, 35…45 mm]; ±2000 µm [0…5 mm, 45…50 mm] |
Housing material | PBT |
Material sensing surface | PBT |
Connection | Connector, M12x1-Male, 3-pin |
Operating voltage Ub | 20…30 VDC |
Ambient temperature | -10…70 °C |
IP rating | IP67 |
Approval/Conformity | CEWEEE |